Cause: Water flow on tap has been reduced. The
filters accumulate dirt causing a reduction of the water flow capacity.
Lack of pressure in the installation.
Verification: With a manometer, check that the pressure intakes are between
1-5 bar (recommended pressure: 3 bar).
Action: Cleaning the joint 3/4”with filter located
at the water inlets (if needed, its replacement is Ref.JCF).
Extracting the thermostatic cartridge and cleaning the filters with
abundant water.
Temperature is not regulated; temperature goes from cold to hot without intermediate
temperatures.
Cause: Hot and cold water inlets are inverted.
Solution: Verifying during the installation that hot water goes
in through the left of the thermostatic. If it is not the case, the installer
should be demanded to adjust the installation.
Verifying that the thermostatic has not been assembled
inside out (the hot water intake is marked or the right position of the tap can
be checked in the catalogue)
The temperature
range has been reduced.
Cause: The filters accumulate dirt causing a reduction of the water flow capacity.
Action: Cleaning
the joint 3/4”with filter located at the water inlets (if needed, its
replacement is Ref. JCF).
Cleaning
thermostatic cartridge, plunging it in vinegar for 24 hours and rinsing it with
abundant water right after.
If it still
can’t be recovered, thermostatic cartridge must be changed for a new one.
Cause: Service
conditions have been modified (pressures and/or supplying temperature).
Action: Readjusting comfort temperature according to cartridge regulation instructions.
Does not regulate. Water ALWAYS comes out at the same
temperature, even when moving the temperature handle to the extremes of cold
and hot water.
Cause: The
thermostatic cartridge has stopped regulating because the internal piston that
tilts the water flow has seized up due to disuse, impurities or lime
accumulation.
Dirt in the
filters has reduced the water flow capacity and does not allow the water mix.
Action: Cleaning
the joint 3/4”with filter located at the water inlets (if needed, its
replacement is Ref. JCF).
Cleaning
thermostatic cartridge, plunging it in vinegar for 24 hours and rinsing it with
abundant water right after.
If it still
can’t be recovered, thermostatic cartridge must be changed for a new one.
Maximum temperature of mixed water comes out lukewarm but not hot (<38ºC). If temperature handle is turned to cold water, the water comes completely cold (15ºC).
Cause: Cold water dominates hot water and does not
allow enough hot water in the tap for its proper temperature adjustment.
Pressure at
water inlets has to be compensated. The thermostatic cartridge accepts a maximum
of 1 bar pressure difference between both intakes.
Verification:
In order to
verify in a simple manner if there is a difference of pressures in the intakes,
another tap can be opened at its maximum water flow and in cold position (if
possible, within the same room) to check at the same time if the hot water
temperature of the thermostatic tap increases.
Action: Installing reducer or pump pressure for both
water intakes to be regulated up to a 3 bar pressure.
Verifying
that there is no anomaly in the ACS installation zone where the pressure drop
takes place (for example: heating coil on the boiler is plugged, reduced pipe
section due to squashing, deficient welding or there are remnants of shells
from the construction…). If it is the case, it must be repaired.
Attenuation
of the problem:
These
simple actions, without modifying the installation, can improve the efficiency
of the thermostatic:
- Slightly
closing the cold water stopcock in the room where the tap is being installed.
-
Decreasing the hot water temperature in the boiler. This way, the thermostatic
will demand a larger quantity of hot water and the thermostatic cartridge will
jam the cold water flow.
Mixed water temperature comes out hot from the sprayer
but cold from the shower handle.
Cause: Cold water dominates hot water and does not
allow enough hot water in the tap for its proper temperature adjustment.
Pressure at
water inlets has to be compensated. The thermostatic cartridge accepts a
maximum of 1 bar pressure difference between both intakes.
Since the
water demand of the sprayer doubles that of the shower handle, the tap must
supply more water and allow a larger hot water inlet.
Action: Installing reducer or pump pressure for both
water intakes to be regulated up to a 3 bar pressure.
Verifying
that there is no anomaly in the ACS installation zone where the pressure drop
takes place (for example: heating coil on the boiler is plugged, reduced pipe
section due to squashing, deficient welding or there are remnants of shells
from the construction…). If it is the case, it must be repaired.
Attenuation
of the problem:
These
simple actions, without modifying the installation, can improve the efficiency
of the thermostatic:
- Slightly
closing the cold water stopcock in the room where the tap is being installed.
-
Decreasing the hot water temperature in the boiler. This way, the thermostatic
will demand a larger quantity of hot water and the thermostatic cartridge will
jam the cold water flow.
Cause: The boiler trigger (membrane) is regulated
for a superior water demand than the water flow required by the shower handle
and the trigger goes off intermittently.
Action: Adjusting the boiler trigger to be activated
with less water demand.
Attenuation
of the problem:
Decreasing
the hot water temperature in the boiler. This way, the thermostatic will demand
a larger quantity of hot water and the thermostatic cartridge will jam the cold
water flow.
Mixed water temperature comes out hot from the shower
handle but cold from the sprayer.
Cause: If when changing from the shower handle to
the sprayer temperature decreases, it can be due to a power insufficiency at
the boiler (boiler of minimum 10l/min is required).
In the
sprayer, the water demand doubles that of The water demand of the sprayer
doubles that of the shower handle and, therefore, the capacity of the oiler is
altered.
The lack of
power in the boiler also produces temperature fluctuations.
Action: Verifying the capacity of the boiler and
contacting a technician to check the state of the boiler. Increasing the
provision temperature up to 65ºC (maximum allowed).
Simple
verification that can be applied by the user about the capacity of the boiler:
Opening in
shower handle position, opening another tap to its maximum water flow in hot
water position (if possible, within the same room) and comparing if the
temperatures are similar (in the thermostatic it is usually slightly inferior
because it always mixes a small proportion of cold water).
Inserting a
cold water flow limiter in the sprayer to reduce the capacity (consult
availability Ref. JLC12).
Temperature cannot be regulated, the handle is
blocked.
Cause: The thermostatic cartridge is blocked due to
the lime adhered to its axis.
Action: Dismantling the cartridge from the tap, plunging
it in vinegar for 24 hours and rinsing it with abundant water right after.
If it still
can’t be recovered, thermostatic cartridge must be changed for a new one.
Cause: The temperature limiter ring as gone out of
place, blocking the spin of the handle.
Action: Levering on the side tap of the handle,
unscrewing the screw on the central part of the handle and extracting the
handle.
Verifying
that the limiter ring (white plastic piece) is appropriately assembled. If it
is loose, it has to be placed again aligning the relief line in the inferior
diameter of the limiter ring with the serigraphed line on the body, and when
assembling the handle, it also has to be aligned with the 38ºC symbol.
In the rest of the tapware of the residence in cold
water position only lukewarm water can be obtained.
Cause: The cold water anti-return valve (right side)
does not work and it is allowing the water mix in the installation.
This can be
due to being blocked because of accumulation of dirt or deterioration.
Action: The anti-return valve is located in the
interior of the tap, right at the water inlets. The joint has to be taken out
with filter to access the anti-return valve. Apply slight pressure at the
central part of the valve and verify that it is not blocked because of
accumulation of dirt.
In order to
replace the anti-return valve (Ref. ARD15), the elastic ring and the
anti-return valve have to be extracted with a screwdriver or a bended tile that
allows pulling outwards.
After opening, closing and opening the tap back again in
hot water position, it takes a lot of time to recover the temperature.
Cause: After opening, closing and opening the tap
back again in hot water position, it takes a lot of time to recover the
temperature.
Action: The anti-return valve is located in the
interior of the tap, right at the water inlets. The joint has to be taken out
with filter to access the anti-return valve. Apply slight pressure at the
central part of the valve and verify that it recovers the movility until its
closing. If it is not the case, it has to be verified that it is not blocked
because of accumulation of dirt.
In order to
replace the anti-return valve (Ref. ARD15), the elastic ring and the anti-return
valve have to be extracted with a screwdriver or a bended tile that allows
pulling outwards.
After a certain amount of time of usage or action, the
thermostatic cartridge has started to lose wáter
Cause: The external toric joints of the cartridge
have been deteriorated during its assembly/dismantling.
The
interior joint of the cartridge has been deteriorated.
Action: Thermostatic cartridge must be replaced with
a new one.
A noise can be heard in the thermostatic tap.
Cause: The installation presents a section reduction
that increases the speed of the fluid and causes flow turbulences.
The pipe is
loose and the counter pressure offered by the fluid makes the pipe vibrate.
Action: It is an installation defect. Consult a
plumber.
Cause: In the interior of the tap there is a protuberance
which generates turbulences when it collides with the fluid.
In this
case it can be due to:
- Remnants
of material from the construction were left inside the tap.
- Tap
smelting flaw.
Action: Cleaning the joint 3/4”with filter located at
the intakes.
Dismantling
the thermostatic cartridge and rinsing with abundant water.
Dismantling
the tap and cleaning it. For large showers, make sure that there are no
impurities in the water outlet of the bar.
If in spite
of having cleaned all parts the noise persists and the thermostatic tap is
still under warranty, contact the distributer to ask for its replacement.